What was found
FWD CARGO BAY INTERCOSTAL SUPPORT ANGLE CRACKED AT BS 500H, STRINGER 25L. ACFT GROUNDED. REMOVED & REPLACED THE SUPPORT ANGLE IAW DWG 143A7505 REV A & B, AND SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO BAY INTERCOSTAL SUPPORT ANGLE CRACKED AT BS 500H, STRINGER 25L. ACFT GROUNDED. REMOVED & REPLACED THE SUPPORT ANGLE IAW DWG 143A7505 REV A & B, AND SRM 51-40-02.