What was found
DURING TOUCHDOWN, FUEL READOUT IN FMC BLANKED OUT, FMC SHOWED "INSUFFICIENT FUEL" AND THE YELLOW FMC LIGHT ILLUMINATED. ACFT GROUNDED. PERFORMED BITE OF FMCS IAW FIM 34-61-00-810-801. NO FAULTS NOTED. PERFORMED OPS CHECK OF FQIS IAW AMM 28-41-00-710-801. NO DEFECTS NOTED. PERFORMED FQIS BITE IAW AMM 28-41-00-810-801. NO FAULTS NOTED. ACCOMPLISHED FIM TASK 34-61-00-810-826. NO FAULTS OR WIRING DEFECTS NOTED DURING GROUND VERIFICATION.