What was found
FLOORBEAM AT BS 986.5 BL31R HAS CORROSION UPPER SURFACE. ACFT GROUNDED. REMOVED CORROSION IAW SRM 53-70-51. PERFORMED DVI IAW SRM 53-70-51. ACCOMPLISHED HFEC IAW NDT MANUAL 51-00-00, PROC .236 PT 6 NO CRACK INDICATIONS. FABRICATED REPAIR PARTS, SPOT FACED, PERFORMED DYE PENETRANT INSPECTION, ROTO PEENED OVERSIZED HOLE. ACCOMPLISHED HFEC OF HOLE WITH NO CRACK INDICATIONS AND INSPECTED ADJACENT STRUCTURE WITH NO OTHER DAMAGE NOTED IAW REO-G20137, REV IR AND REV A ALODINED IAW SRM 51-20-01. PRIMED IAW SOPM 20-41-02. INSTALLED REPAIR IAW REO-G20137, REV IR AND REO-G20137, REV A .