What was found
MAIN CABIN FLOOR STRUCTURE IN FORWARD WET AREA, BS 312 - 328, LBL 46.6, WL 208.1 CRACKED. ACFT GROUNDED. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, AND DWG 141A5400 SHT 26 REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FLOOR STRUCTURE IN FORWARD WET AREA, BS 312 - 328, LBL 46.6, WL 208.1 CRACKED. ACFT GROUNDED. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, AND DWG 141A5400 SHT 26 REV-.