What was found
AFT PIT FLOOR SUPPORT, BS 767+4, RBR 13.84 IS CORRODED. ACFT GROUNDED. REMOVED CORROSION ORIGINAL THICKNESS .070, REMOVED .014 REMAINING MATERIAL IS .056 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2, DETAIL-D/F FIG 103 USED UT GAGE T8225V, REPAIRED FLOOR SUPPORT AREA IAW SRM 53-00-53-2R3. PO 815766.1, PO 832120.2, DOT REMOVED.