What was found
APU OIL AT CDU INDICATES LOW. ACFT GROUNDED. VERIFIED OIL LEVEL AT APU FULL, PERFORMED FIM 49-90, TASK 804. FOUND MESSAGE NR 49-91227. R & R OIL QTY SENSOR, REF AMM 49-94-11. NO FURTHER FAULTS OR DEFECTS NOTED, OPS CHECK NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU OIL AT CDU INDICATES LOW. ACFT GROUNDED. VERIFIED OIL LEVEL AT APU FULL, PERFORMED FIM 49-90, TASK 804. FOUND MESSAGE NR 49-91227. R & R OIL QTY SENSOR, REF AMM 49-94-11. NO FURTHER FAULTS OR DEFECTS NOTED, OPS CHECK NORMAL.