B-SIDE FAULT IN NR 2 ENGINE OVERHEAT DETECTOR. ACFT GROUNDED. REMOVED AND INSTALLED NEW UPPER FAN DETECTOR ELEMENT REF AMM 26-11-01-000-801. PERFORMED NR 2 ENGINE FIRE DETECTION. OPS TEST, TASK 26-11-00-710-801. SYS CHECKS NORMAL.