What was found
WHILE PERFORMING TASKCARD 78273000, FMC, CDU FAULTS FOUND A FAULT ON THE NR 1 ENGINE, FAULT CODE 75-10371, HMU VSV IS OUT OF RANGE. SHORT TERM FAULT OF 50 HRS. ACFT GROUNDED. R & R J5 HARNESS, REF AMM 73-21-06. ELECTRONIC ENGINE CONTROL TEST GOOD, REF AMM 73-21-00, AND ACTUATOR TEST PASSED, REF AMM 71-00-00-700-807. NO FAULTS NOTED.