What was found
AFT CARGO FLOOR SUPPORT HAS CORROSION BETWEEN BS 767 AND 787, STRINGER 25 AND 26R. ACFT GROUNDED. BLEND OUT AREA FOUND OUT OF LIMITS. IAW SRM 53-60-15-1A-1, LOCATED DRILLED AND INSTALLED NEW FLOOR SUPPORT IAW DWG 14A0081-REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO FLOOR SUPPORT HAS CORROSION BETWEEN BS 767 AND 787, STRINGER 25 AND 26R. ACFT GROUNDED. BLEND OUT AREA FOUND OUT OF LIMITS. IAW SRM 53-60-15-1A-1, LOCATED DRILLED AND INSTALLED NEW FLOOR SUPPORT IAW DWG 14A0081-REV A.