What was found
AFT CARGO FRAME SPLICE GOUGED BS 727L STRINGER 25R. ACFT GROUNDED. REMOVED AND REPLACED THE FRAME SPLICE IAW SRM 51-40-02, DWG 146A1300 REV G, AND 146A125 REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO FRAME SPLICE GOUGED BS 727L STRINGER 25R. ACFT GROUNDED. REMOVED AND REPLACED THE FRAME SPLICE IAW SRM 51-40-02, DWG 146A1300 REV G, AND 146A125 REV-.