What was found
FWD CARGO FLOOR SUPPORT HAS CORROSION BETWEEN BS 500K AND 500L RBL 14. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 103. REMOVED DAMAGED SECTION OF THE FLOOR SUPPORT.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO FLOOR SUPPORT HAS CORROSION BETWEEN BS 500K AND 500L RBL 14. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 103. REMOVED DAMAGED SECTION OF THE FLOOR SUPPORT.