Service difficulty report · Warning Light · Boeing 737890

Difficulty date
September 30, 2016
Submitted
October 3, 2016
Operation
Air carrier
Aircraft
N566AS
Make and model
Boeing 737890
Aircraft serial
35182
Aircraft time
37,531 hours, 11,269 cycles
Part
Warning Light
Condition
False Activation
Location
Zone Temp
Stage of operation
NR
How discovered
V
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ZONE TEMP ILLUMINATED ON RECALL LIGHT EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED ZONE TEMP CONTROLLER BITE ON BOTH CONTROLLERS IAW AMM 21-61-00, ZONE TEMP CONTROLLER NR 2 FAULTED "FLT DECK TRIM VALVE", CLEANED FLT DECK SENSOR AND FILTER, RETESTED ZONE TEMP CONTROLLER NR 2 TWO MORE TIMES AND FAULT DID NOT COME BACK, ZONE TEMP DOES NOT ILLUMINATE ON RECALL, GROUND VERIFICATION SUCCESSFUL.