What was found
FWD CARGO BAY UNDER TRANSITION PANEL, ATTACH ANGLE AT FWD END OF FRAME, CRACKED BS 500H, STRINGERS 24-25R. ACFT GROUNDED. REMOVED AND REPLACED THE ATTACH ANGLE IAW SRM 51-40-05, 51-40-02, AND DWG 143A7505.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO BAY UNDER TRANSITION PANEL, ATTACH ANGLE AT FWD END OF FRAME, CRACKED BS 500H, STRINGERS 24-25R. ACFT GROUNDED. REMOVED AND REPLACED THE ATTACH ANGLE IAW SRM 51-40-05, 51-40-02, AND DWG 143A7505.