What was found
LEFT A/C PACK LIGHT ILLUMINATED. EXTINGUISHES WITH MASTER CAUTION RECALL. ACFT GROUNDED. VERIFIED THE LT PACK LIGHT FAULT LIGHT, RESET AFTER MASTER CAUTION, IAW FIM 21-62 TASK 801, PERFORMED PACK TEMP CONTROL BITE PROCEDURE, THIS PACK TCV LIGHT FLAGGED. AFTER VERIFY, GREEN LIGHT "GO" ILLUMINATED, AND THE FAULT RESET, PACK LIGHT NO LONGER ILLUMINATED. PERFORMED BITE PROCEDURE TWICE AND NO FAULTS WERE DETECTED. OPS CHECK GOOD.