What was found
NR 2 ENGINE WOULD NOT START, NO FUEL FLOW. ACFT GROUNDED. REMOVED AND REPLACED THE NR 2 ENG RT IGNITER PLUG IAW AMM 74-21-02 AND RT IGNITION LEAD IAW AMM 74-21-01. IGNITER AND IGNITION LEAD TESTS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 ENGINE WOULD NOT START, NO FUEL FLOW. ACFT GROUNDED. REMOVED AND REPLACED THE NR 2 ENG RT IGNITER PLUG IAW AMM 74-21-02 AND RT IGNITION LEAD IAW AMM 74-21-01. IGNITER AND IGNITION LEAD TESTS NORMAL.