What was found
AFT CARGO FLOOR PANEL 140AF DENTED AND SCRATCHED ALL ARROUND. ACFT GROUNDED. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53. FABRICATED A NEW FLOOR PANEL IAW DWG 453A2610-33, ALODINED IAW SRM 57-21-01, PRIMED IAW SOPM 20-41-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO FLOOR PANEL 140AF DENTED AND SCRATCHED ALL ARROUND. ACFT GROUNDED. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53. FABRICATED A NEW FLOOR PANEL IAW DWG 453A2610-33, ALODINED IAW SRM 57-21-01, PRIMED IAW SOPM 20-41-02.