What was found
AFT CARGO FLOOR PANEL 140CF DENTED AND SCRATCHED. ACFT GROUNDED. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. FABRICATED A NEW FLOOR PANEL IAW DWG 453A2610. ALODINED IAW SRM 51-20-01. AND PRIMED IAW SOPM 20-41-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO FLOOR PANEL 140CF DENTED AND SCRATCHED. ACFT GROUNDED. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. FABRICATED A NEW FLOOR PANEL IAW DWG 453A2610. ALODINED IAW SRM 51-20-01. AND PRIMED IAW SOPM 20-41-02.