What was found
AFT MAIN CABIN R-2 DOOR SILL SUPPORT HAS CORROSION BETWEEN BS 947.05 AND BS 995 , RBL 60. GROUNDED - YES. EVALUATED DAMAGE CORROSION FOUND OUT OF LIMITS, ORIGINAL MATERIAL THICKNESS IS .080, REMOVED .026, REMAINING IS .054 IAW SRM 53-70-15 REMOVED AND REPLACED NEW CHORD PO 879784.3 IAW SRM 51-40-02 AND DWG 147A8501, REV-, 147A0000 REV - AND 147A060 REV-.