What was found
MAIN CABIN FLOORBEAM T-CAP HAS CORROSION AT BS 987, BETWEEN RBL 12 AND RBL 45. GROUNDED - YES. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-70-51-1A-1, ORIGINAL MATERIAL THICKNESS IS .150 IN. REMAINING IS .136 IN, REMOVED .014 IN REMOVED, EXISTING TEE CAP SECTIONS AND SPLICE IAW SRM 51-40-02, FABRICATED AND INSTALLED NEW T-CAP REPAIR SECTIONS AND SPLICE IAW SRM 53-70-51-2A-4.