What was found
MAIN CABIN FLOOR STRUCTURE, SECTION 41 AT BS 328-BS 344, LBL 45.60, WL 208.1, INTERCOSTAL CRACKED AT FASTENER HOLE LOCATION. GROUNDED - YES. REMOVED AND REPLACED MAIN CABIN FLOOR STRUCTURE , INTERCOSTAL, AT BS 328- BS 344, LBL 45.60, WL 208.1 IAW DRAWING 141A5400 REV- SHEET 28.