What was found
ON RECALL RIGHT PACK LIGHT ILLUMINATES. ACFT GROUNDED. PERFORMED PACK TEMP CONTROL BITE IAW FIM TASK 21-62 TASK 801. TCV FAULT INDICATED. REMOVED AND REPLACED TEMP CONTROL VALVE IAW AMM 21-51-10. LEAK CHECK AND OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON RECALL RIGHT PACK LIGHT ILLUMINATES. ACFT GROUNDED. PERFORMED PACK TEMP CONTROL BITE IAW FIM TASK 21-62 TASK 801. TCV FAULT INDICATED. REMOVED AND REPLACED TEMP CONTROL VALVE IAW AMM 21-51-10. LEAK CHECK AND OPS CHECKED GOOD.