Service difficulty report · Valve · Boeing 737990ER

Difficulty date
December 1, 2016
Submitted
December 9, 2016
Operation
Air carrier
Aircraft
N413AS
Make and model
Boeing 737990ER
Aircraft serial
35205
Aircraft time
14,773 hours, 4,764 cycles
Part
Valve
Part number
32149721
Part serial
3850
Condition
Failed
Location
Lt Temp
Part time
13,121 hours, 4,261 cycles
Stage of operation
NR
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

COCKPIT AIR TEMP GAUGE DOES NOT ACCURATELY REFLECT THE TEMPERATURE SUPPLY DUCT, PAX CABIN, PACK TEMPS ALL READING AT OR BELOW 10 DEG C. F/A REPORTED CABIN TEMP OK OR SLIGHTLY WARM. ACFT GROUNDED. REMOVED & REPLACED THE TEMPERATURE CONTROL MODULE, IAW AMM 21-61-15/401. NO HELP. WHEN SELECTING ZONE TEMP CONTROL KNOBS TO FULL WARM TEMPERATURE DOES NOT CHANGE IN CABIN OR GAUGE. TROUBLESHOOT IAW FIM 21-61 TASK 861. PACK TEMP CONTROL BITE SHOWS NO FAULTS. REMOVED & REPLACED TRIM AIR PRESSURE REGULATING AND SHUTOFF VALVE IAW AMM 21-62-01/401. OPS CHECKED NORMAL. TEMP CONTROL INDICATION CHECKED NORMAL IN ALL POSITIONS.