Service difficulty report · Filter · Boeing 737890

Difficulty date
December 4, 2016
Submitted
December 6, 2016
Operation
Air carrier
Aircraft
N566AS
Make and model
Boeing 737890
Aircraft serial
35182
Aircraft time
38,216 hours, 11,460 cycles
Part
Filter
Condition
Clogged
Location
Temp Sensor
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL, EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. REMOVED AND REPLACED A CLOGGED FILTER AND CLEANED TEMP SENSOR. ACCOMPLISHED PACK TEMP CONTROL BITE IAW FIM 21-62 TASK 801, FAULTED FLT DECK TRIM VALVE ON ZONE TEMP CONT #2 (M1443). CLEARED FAULT AND "ZONE TEMP" LIGHT DID NOT ILLUMINATE ON RECALL.