What was found
CRACK INDICATION AT HSS 129.5, APPROX. 1 INCH IN LENGTH, 4 INCHES AFT OF EXISTING REPAIR EDGE. ACFT GROUNDED. LOCATED AND REMOVED DAMAGE AREA IAW SRM 55-10-01, FABRICATED FILLER AND DOUBLER IAW SRM 55-10-01-2R-11, ALODINED AND PRIMED FILLER AND DOUBLER IAW SRM 51-20-01, INSTALLED FILLER AND DOUBLER IAW B737-800 SRM 51-40-02.