What was found
MAIN CABIN AFT WET AREA FLOOR SUPPORT ANGLE CORRODED BS 1010, LBL 31, WL 207.5. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02, AND FOUND OUT OF LIMITS IAW SRM 53-70-51, REMOVED THE FLOOR SUPPORT ANGLE IAW SRM 51-40-02, LOCATED,DRILLED AND INSTALLED A NEW FLOOR SUPPORT ANGLE IAW DWG 147A5700 REV- AND SRM 51-40-02.