What was found
MAIN CABIN FLOOR WEB CORRODED BS 992-1016, RBL 33-42, WL 207.5. ACFT GROUNDED. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-70-51. REMOVED AND REPLACED THE WEB IAW DWG 147A5700 REV-, SRM 51-40-02, SRM 51-40-05, AND SRM 51-10-02.