What was found
MAIN CABIN AFT WET AREA FLOOR CORRODED. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02. FOUND TO BE BEYOND ALLOWABLE LIMITS OF 20%. REMOVED AND REPLACED THE STRAP IAW SRM 51-40-02, SRM 51-40-05 AND DWG 147A5700 REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN AFT WET AREA FLOOR CORRODED. ACFT GROUNDED. REMOVED CORROSION IAW SRM 51-10-02. FOUND TO BE BEYOND ALLOWABLE LIMITS OF 20%. REMOVED AND REPLACED THE STRAP IAW SRM 51-40-02, SRM 51-40-05 AND DWG 147A5700 REV-.