What was found
PER TASK CARD 78273000 ECONOMIC FAULT FOUND MSG 73-31372 ON NR 2 ENGINE. GROUNDED - YES. INSPECTED AND FOUND S1 OUT OF LIMITS BY PERFORMING LINE RESISTANCE CHECK. S4 PROBE IS WITHIN LIMITS. RMVD AND INSTALLED NEW S1 T49.5 PROBE REF AMM TASK 77-21-01-400-801-F00 . ACCOMPLISHED NR 2 ENG EEC TEST REF AMM 73-21-00-700-804-F00. PROBE READINGS S1=53.80, S2=22.29, S3=24.20, S4=56.13. AFTER CLEANING S1=20.98, S2=11.02, S3=10.42,S4=24.32. THIS CLEARS L0NG TERM PLT.