What was found
CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED DURING RECALL. ACFT GROUNDED. ACCOMPLISHED A PACK TEMP CONTROL BITE IAW FIM 21-62 TASK 801. FOUND FLT DECK TRIM VALVE FAULT LATCHED. RESET LATCH. OPS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED DURING RECALL. ACFT GROUNDED. ACCOMPLISHED A PACK TEMP CONTROL BITE IAW FIM 21-62 TASK 801. FOUND FLT DECK TRIM VALVE FAULT LATCHED. RESET LATCH. OPS NORMAL.