Service difficulty report · Shutoff Valve · Boeing 737890

Difficulty date
January 22, 2017
Submitted
February 3, 2017
Operation
Air carrier
Aircraft
N538AS
Make and model
Boeing 737890
Aircraft serial
41188
Aircraft time
18,447 hours, 5,380 cycles
Part
Shutoff Valve
Part number
32145526
Part serial
4409
Condition
No Test
Location
Nr 1 Engine
Part time
60,472 hours, 28,549 cycles
Stage of operation
CL
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CLIMB FL 390 100% N1, LEFT DUCT PRESSURE 22PSI, RIGHT DUCT PRESSURE 42 PSI. ACFT GROUNDED. CHECKED AND RELEASED IAW FIM TASK 36-10/811, FOR A PERIOD OF 10 DAYS. FOUND TO BE WITHIN LIMITS. ACCOMPLISHED NR 1 ENGINE BLEED AIR SYSTEM HEALTH CHECK IAW TASK CARD NG-36WC-00001. FOUND PRSOV AND PRECOOLER VALVE FAILED DURING THE TEST. REPLACED PRSOV IAW AMM 36-11-04-400-801, LEAK AND OPS CHECKED GOOD. REPLACED PRE COOLER VALVE IAW AMM 36-12-02-400-801, LEAK AND OPS CHECKED GOOD. ACCOMPLISHED ENG BLEED AIR CROSSOVER TEST, TEST FAILED. REPLACED BLEED AIR REGULATOR IAW AMM 36-11-03-400-801, LEAK AND OPS CHECKED GOOD. PERFORMED ENG BLEED AIR CROSSOVER OPERATIONAL TEST AGAIN, TEST PASSED.