What was found
AFTER STARTUP CONTROL CAB ZONE TEMP LIGHT CAME ON AND WOULD NOT EXTIGUISH AFTER CHECKLIST. ACFT GROUNDED. PERFORMED FIM 21-61 TASK 861. BITE TEST OF NR 1 AND 2 TEMP CONTROLLERS SHOWS NO FAULTS. RAN PACKS AND CONT CABIN TEMP ADJUSTS NORMALLY. BITE TESTED AGAIN AND NO FAULT. NO HISTORY 90 DAYS.