What was found
FWD CARGO BAY RT FLOOR PANEL CORRODED FROM BS 500B - 500L. ACFT GROUNDED. REMOVED CORROSION. FABRICATED A REPAIR AT BS 500+9 IAW SRM 53-00-53-2R-5, INSTALLED THE REPAIR IAW SRM 51-40-02, DWG 143A7500 REV A, AND SRM 53-00-53 -2R-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO BAY RT FLOOR PANEL CORRODED FROM BS 500B - 500L. ACFT GROUNDED. REMOVED CORROSION. FABRICATED A REPAIR AT BS 500+9 IAW SRM 53-00-53-2R-5, INSTALLED THE REPAIR IAW SRM 51-40-02, DWG 143A7500 REV A, AND SRM 53-00-53 -2R-5.