What was found
NR 2 IDG DELTA P POPPED. ACFT GROUNDED. USED ALTERNATE DEACTIVATION PROCEDURES IAW CHAPTER 5 TABLE 3 ITEM 1, REPLACED IDG OIL FILTERS IAW AMM 24-11-41, NO CONTAMINATION NOTED, RESET DELTA P, REVERSED DEACTIVATION PROCEDURES, PERFORMED ENGINE RUN NO LEAKS NOTED.