What was found
AT CRUISE R2 WINDSHIELD OVERHEAT LIGHT ILLUMINATED, PERFORMED QRH CHECKLIST, LIGHT REMAINED OUT. ACFT GROUNDED. NUMEROUS FAULT FOR SENSOR ON WHCU BITE. RESISTANCE CHECKED FOR WINDOW COLD & EXTENDED HEAT APPLIED SHOW SAME VALUE WITHIN LIMITS, IAW AMM 30-41-21 & WDM 30-41-11. REPLACED COIL CORD, WINDOW HEAT OPERATIONAL TEST PASSED.