AFT CARGO COMPARTMENT FLOOR PANEL 140DF CORRODED ALONG EDGE. GROUNDED - YES. FABRICATED, LOCATED AND DRILLED NEW PANEL IAW SRM 51-40-05-0G-0 W 1IN O .071 R .030 L 61IN. D .040.