What was found
FWD PIT FLOOR PANEL HAS MINOR CORROSION ALONG EDGE 120AF. GROUNDED - YES. PANEL 120AF SCRATCHES MORE THAN 3" OUT OF LIMITS IAW SRM 53-00-53. FABRICATED, ALODINED AND PRIMED PANEL 120AF IAW DWG 453A1610 AND SOPM 20-41-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PIT FLOOR PANEL HAS MINOR CORROSION ALONG EDGE 120AF. GROUNDED - YES. PANEL 120AF SCRATCHES MORE THAN 3" OUT OF LIMITS IAW SRM 53-00-53. FABRICATED, ALODINED AND PRIMED PANEL 120AF IAW DWG 453A1610 AND SOPM 20-41-01.