What was found
FWD PIT FLOOR PANEL 120BF HAS MINOR CORROSION ALONG EDGE. GROUNDED - YES. FABRICATED FWD PIT PANEL 120BF PER DWG 453A1610 REV T. ALODINED AND PRIMED PER DWG 453A1610 REV T.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PIT FLOOR PANEL 120BF HAS MINOR CORROSION ALONG EDGE. GROUNDED - YES. FABRICATED FWD PIT PANEL 120BF PER DWG 453A1610 REV T. ALODINED AND PRIMED PER DWG 453A1610 REV T.