As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT PACK LIGHT ILLUMINATED ON RECALL, AND LIGHT EXTINGUISHED ON RESET. ACFT GROUNDED. PERFORMED PACK ZONE TEMP CONTROLLER BITE TEST IAW FIM 21-61-00. SATISFACTORY, OPERATED BOTH PACKS FOR 20 MINUTES. NO FAULTS. PERFORMED PACK ZONE TEMP CONTROLLER BITE TEST IAW FIM 21-61-00. NO FAULTS.