What was found
ON ENG START, NR 2 START LEVER RAISED TO IDLE, NO FUEL FLOW, ENG VALVE CLOSED ANNUNCIATOR ILLUMINATED BRIGHT ONLY. QRH PROCEDURES ACCOMPLISHED FOR ABORTED START. GROUNDED - YES. NR 2 EEC BITE CK FND MX MESSAGE 73-31552. DID FIM 73-31 TASK 803, NO OTHER MX MESSAGES. HPSOV CK OF CONTROL PWR STEP F (2) IS NML. ENG FUEL SPAR VALVE ELEC CONTROL AND INDICATION TEST IS NML REF AMM 28-22-00-710-801. FIM 80-06 TASK 801 STEP E(1) CK OF NR 2 EEC INPUT DISCRETES IS NML. PUT A/C BACK TO NML CONFIGURATION. START AND RAN NR 2 ENG WITH NO FAULTS. REPLACED NR 2 ENG START BRAKE ASSY M1825 REF AMM 76-11-10. COMPLETED OPS CHECKS REF AMM 76-11-10-420-801-F00 STEP 3 H 1-4. ALL OPS CHECKS NORMAL. DEFECT CLEARED.