What was found
FLOOR SUPPORT BS 947.5 - 967, RBL 50 HAS CORROSION. ACFT GROUNDED. EVALUATED CORROSION AND FOUND IT TO BE OUT OF LIMITS IAW SRM 53-70-51. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02 AND DWG 147A5650, SHEET 44, REV -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT BS 947.5 - 967, RBL 50 HAS CORROSION. ACFT GROUNDED. EVALUATED CORROSION AND FOUND IT TO BE OUT OF LIMITS IAW SRM 53-70-51. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02 AND DWG 147A5650, SHEET 44, REV -.