As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM AT STA 947.5 HAS CORROSION FROM RBL49-RBL54. GROUNDED - YES. EVALUATED CORROSION ON THE UPPER SURFACE OF THE T-CAP OF FLOORBEAM AT BS 947.5, FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51. ACCOMPLISHED A CATEGORY "A" REPAIR TO THE FLOORBEAM AT BS 947.5 LBL 8 - RBL 60 IAW SRM 53-70-51-2R-5 REPAIR 5.