As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHILE ACCOMPLISHING T/C NG-28FCD-18090-1, FQIS NO. 2 TANK & COMPENSATOR UNITS TESTING, FOUND FUEL PROBES NR 1, 3, 10 & COMPENSATOR OUT OF LIMITS. ACFT GROUNDED. REMOVED AND REPLACED THE PROBE (F15R) TANK UNIT NR 1 AND 3 IAW AMM 28-41-21-400-801. REMOVED AND REPLACED TANK UNIT 10 IAW AMM 28-41-21-400-801. ACCOMPLISHED FQIS, SYSTEM TEST OF NR 2 TANK IAW AMM 28-41-00. OPS NORMAL.