What was found
ON ROTATION "FLT CONT" ILLUMINATED MOMENTARLY. GROUNDED - YES. INSPECTED AIRCRAFT FOR HYDRAULIC LEAKS, NONE NOTED. INSPECTED HYDRAULIC SYSTEM QTY A & B AND FOUND THEM TO BE WITHIN SERVICEABLE LIMITS PER AMM 12-12-00. ACCOMPLISHED FLIGHT CONTROL PANEL INSTALLATION TEST PER AMM 27-09-45 PARAGRAPH 5 A-G. NO DEFECTS NOTED. ACCOMPLISHED LOW PRESSURE WARNING SWITCH TEST PER AMM 27-09-61. NO DEFECTS NOTED. CYCLED FLIGHT CONTROLS THROUGH FULL RANGE OF MOTION. NO FLIGHT CONTROL ELEVATOR FEEL OR HYDRAULIC PRESSURE ISSUES NOTED.