What was found
CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL, EXTINGUISHED ON RECALL. ACFT GROUNDED. CONTROL CABIN TRIM MODULATING VALVE FAILED A BITE TEST. REMOVED AND REPLACED CONTROL CABIN TRIM MODULATING VALVE IAW AMM 21-61-21-000-801, AND 21-61-21-400-801. GROUND FUNCTIONAL TESTED GOOD IAW AMM 21-61-21-00-700-806-002.