Service difficulty report · Connector · Boeing 737990ER

Difficulty date
June 4, 2017
Submitted
June 5, 2017
Operation
Air carrier
Aircraft
N434AS
Make and model
Boeing 737990ER
Aircraft serial
61620
Aircraft time
4,998 hours, 1,592 cycles
Part
Connector
Part number
BACC45FT105S
Condition
Disconnected
Location
Cabin Temp
Stage of operation
TX
How discovered
O
Nature of condition
J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER ENGINE START DURING MASTER CAUTION RECALL, FWD CAB ZONE TEMP ANNUNCIATOR ILLUMINATED. UNABLE TO DEMONSTRATE TEMPERATURE CONTROL REQUIRED BY MEL 21-19F FWD/AFT OPERATIONS PROCEDURES. THE ANNUNCIATOR DID EXTINGUISH WITH MC RESET. ACFT GROUNDED. ACCOMPLISHED FIM 21-62 TSK 843, VERIFIED ABOVE REFERENCED FAULT. INSPECTED FWD ZONE TEMP SENSOR AND FOUND CONNECTOR D15016 DISCONNECTED. RECONNECTED D15016 TO FWD ZONE TEMP SENSOR, FAULTS NOW RESET AND REPAIR CONFIRMATION IS GOOD IAW FIM 21-62 TSK 843 AND 21-53 TSK 803.