What was found
AFT CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. CLEARED ZONE TRIM VALVE FAULT ON NR 1 PACK/ZONE TEMP CONTROLLER. BOTH PACK/ZONE TEMP CONTROLLERS BITE CHECKED NORMAL IAW AMM 21-61-00. GROUND VERIFICATION SUCCESSFUL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. CLEARED ZONE TRIM VALVE FAULT ON NR 1 PACK/ZONE TEMP CONTROLLER. BOTH PACK/ZONE TEMP CONTROLLERS BITE CHECKED NORMAL IAW AMM 21-61-00. GROUND VERIFICATION SUCCESSFUL.