What was found
PSEU LIGHT ILLUMINATED. ACFT GROUNDED. TRA LT 53 FAULT CODE 31-52002 FOUND ON PSEU. CONFIRMED STATUS OF D10982 PIN 42 WOULD NOT CHANGE WITH THRUST LEVER MOVEMENT AS REQUIRED IAW FIM 32-09, TASK 815. REPLACED THE LT AUTOTHROTTLE SWITCH PACK M1766 AND AJUSTED IAW AMM 76-11-07. OPS NORMAL IAW AMM 76-11-07, 32-09-10, 32-42-00, 78-31-00, 30-11-00, 31-51-00, & 34-43-00. REPAIR CONFIRMATION OF FIM 32-09T815 CHECKED NORMAL.