What was found
FLOOR SUPPORT IS CRACKED AT BS 344 - 360, LBL 11. ACFT GROUNDED. REPLACED THE FLOOR SUPPORT IAW DWG 141A5400, REV B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT IS CRACKED AT BS 344 - 360, LBL 11. ACFT GROUNDED. REPLACED THE FLOOR SUPPORT IAW DWG 141A5400, REV B.