What was found
WHILE PERFORMING T/C 78273000, FOUND FAULT MESSAGE 75-20831, THE T3 SIGNAL IS OUT OF RANGE, LONG TIME FAULT NR 1 ENGINE, ACFT GROUNDED. EEC BITE DONE IAW FIM 73-00, TASK 801. FAULT ACTIVE. ACCOMPLISHED T3 CONNECTOR CLEANING IAW FIM 75-33, TASK 802, AND WDM 75-31-11. FOUR CIRCUIT BREAKERS WERE PULLED AND RESET AND ALL CONNECTORS RECONNECTED. REPAIR CONFIRMATION GOOD IAW FIM 75-33, TASK 802. FAULT NO LONGER ACTIVE.