What was found
WHILE ACCOMPLISHING T/C 78273000, A MESSAGE FOR THE RT ENGINE, 75-20802 (T25 SIGNALS DISAGREE) SHORT TIME FAULT. ACFT GROUNDED. PERFORMED FIM 75-33 TASK 805, CHECKED RESISTANCE AT THE T 25 SENSOR. RESISTANCE CHECKED GOOD. CHECKED WIRING FROM CONNECTOR DP0909 TO DP 0910, WIRING CHECKED GOOD. CHECKED WIRING FROM CONNECTOR 1010 TO 1009, WIRING CHECKED GOOD. PERFORMED AN EEC TEST. EEC TEST PASSED, NO FAULTS NOTED IAW AMM 73-21-00.